Shelly Plus Plug IT Device Smart Control
Main Controls
Below the Main Controls heading, observe the current Shelly Device power in Watts (W) and voltage in Volts (V).
Above the power button is a chart of the Shelly Device consumption in watt-hours (Wh) of the last 24 hours, and the Shelly Device’s current power consumption in Watts (W).
The power button ⏻
is at the bottom of this tab. Click the power button ⏻
to turn your device On/Off. Your device is on when there is a blue ring around the power button ⏻
, and is off when the ring is gray.
Notifications
If you have Shelly Device notifications, they will appear on this tab. View the number of notifications for this Shelly Device. Tap the X
button in the top right corner of the notification box if you wish to delete the notification.
Charts
Consumption
Observe a chart with the Shelly Device consumption displayed in Watt-hours (Wh). Above the consumption chart, you can select the time interval and the date from which you want data to be shown.
Below the consumption chart are a variety of Shelly Device measurements. Observe the Eco (compared) value that gives a percentage of how much lower the consumption value is. In addition, also observe the total consumption value in kilo-Watt-hours (kWh), the average consumption in Watt-hours (Wh), and the maximum and minimum consumption in Watt-hours (Wh). Observe the corresponding price next to each of these measurement values.
Click on the expand icon in the top right corner of the Consumption rectangular box if you wish to view the chart in full screen. Click the Export CSV
button to download this data as a CSV file.
Voltage
Observe a chart with the Shelly Device maximum and minimum voltage displayed in Volts (V). Above the voltage chart, you can select the time interval and the date from which you want data to be shown. Drag your finger/mouse across the chart to view time specific voltage measurements. Tap the blue icon to the right of the date interval, above the chart, and change the displayed chart style.
Below the voltage chart are a variety of Shelly Device measurements. Observe the average, maximum, and minimum Shelly Device voltage in Volts (V).
Tap on the expand icon in the top right corner of the Voltage rectangular box if you wish to view the chart in full screen. Tap Export .csv
to download this data as a CSV file.
Activity log
Observe the recorded history of the Shelly Device events. See the date, time and type of action executed such as the Device being switched On/Off.
Timer
In this tab, you can set a timer to manage the device on/off state.
Choose from the following options:
Auto on: Enter the number of seconds that should pass for the device to be switched on after it has been turned off. Mark the empty checkbox to enable the timer.
Auto off: Enter the number of seconds that should pass for the device to be switched off after it has been turned on. Mark the empty checkbox to enable the timer.
Tap Save to confirm the setting.
Schedule
Click the Add schedule
button to create a schedule. Create a weekly schedule for the day(s) and time(s) you want the corresponding device to turn On/Off automatically, or to change to a specified brightness. You may add up to 20 weekly schedules. This function requires a working connection to the Internet.
Choose Weekday: Select the mode as Simple or Advanced for selecting days of the week.
Simple: Choose Simple mode to select day(s) of the week.
Advanced: Switch to Advanced mode for more complex schedules.
Specific days: Click the toggle button to select specific days of the month. When inactive, this function applies to all days of the month. Set the active days of the month by clicking on the desired date(s). You may also select dates using the following buttons:
Select even
Select odd
Input the dates "From" and "To" that you want to set as active dates, then click the
Select
button to choose these dates.Click the
Clear
button to clear selected dates.
Specific months: Click the toggle button to select specific months. When inactive, this function applies to all months. Select the active months using the following buttons:
Select even
Select odd
Input the dates "From" and "To" that you want to set as active dates, then click the
Select
button to choose these dates.Click the
Clear
button to clear selected dates.
Click the
NEXT
button.
Choose time interval: Select the mode as Simple or Advanced.
Simple: Choose Simple mode to select a specific time or intervals based on Sunrise/Sunset. Choose from Time, Sunrise / Sunset, and set the time for the previously selected day(s):
Time: Click up/down button, or type in a number, to set a time in hours and minutes.
Sunset / Sunrise: The Shelly device may turn on/off automatically at sunrise/sunset, or at a specified time Before/After Sunrise/Sunset. Select the time in hours and minutes from the dropdown menus.
Advanced: Choose Advanced mode for more complex schedules. Observe the selected times at which the schedule will be executed at the bottom of this page. Click the toggle button of the following to set them up: Hours / Minutes / Seconds. Set up each of these time units by clicking on the desired time in hours/minutes/seconds, or by clicking on the following buttons:
Select even
Select odd
Input the number "From" and "To" that you want to set as the active time, then click the
Select
button to choose these times.Click the
Clear
button to clear selected time.
Local Action: Click the
+ Add local action
button to add up to 5 actions per schedule. Select Control Output / Toggle Output from the dropdown menu to set the type of local action. If Control Output is selected, select the target component from the dropdown menu, and set the action as On / Off. Click the checkbox to flip value after the set number of seconds, and input the number of seconds. Click theSave
button to save the action. Once a schedule action has been created, click on the action if you wish to edit it, or click the trash icon to the right of it if you wish to delete it.Schedule Details: View schedule details such as the days of the week and the time(s) at which the schedule will be executed, and the type of action.
Click the
Save
button to save the schedule.
Once the schedule has been created, it will appear as a rectangular box on the main Schedule page for the Shelly Device. On this box, you can see the schedule details such as the days of the week, action and time. You can enable/disable a schedule by clicking the toggle button on the left of the schedule box. You can edit the schedule by clicking on the edit pencil icon on the right, and delete the schedule by clicking the trash icon on the right.
Actions
Use events to trigger http endpoints. You can add up to 20 web hooks. Set up the following settings, and navigate between pages by clicking the NEXT
or BACK
buttons. Create an action:
Set Action Name: Type in web hook name.
Active Time: May leave as the 24-hour default option or choose an active start and end time. Click the up/down buttons, or type in a number, to set a time in hours and minutes.
When: Select from a variety of conditions for the button/switch.
Switch on
Switch off
Then Do: Input URL to send the Shelly Device a command. You may add up to 5 URLs per action, which will be executed one after the other. Click the
Add
button to add another URL to execute, or click theAdd local action
button to configure a local action.Local action: Select Control Output / Toggle Output from the dropdown menu to set the type of local action. Set the action as On / Off. Click the checkbox to flip value after the set number of seconds.
Click the
SAVE
button to save the web hook or to save any changes made.
This function requires a working connection to the Internet. Once the action has been created, it will appear as a rectangular box on the main I/O actions page for the Shelly Device. You can enable/disable an action by click the checkbox to the left of the action box. You can edit the schedule by clicking on the edit pencil icon on the right, and delete the action by clicking the trash icon on the right.
Scripts
Use the Scripts functionality to create or import scripts.
Library: Click the
Open Library
button to view existing scripts. Click on the desired script and click theInsert code
button to add the script to your Shelly Device.Create new script: Click the
Create new script
button. A new page will appear where you can name, create, edit and save your script. Click the play button to run your script. Click thex
button to exit the script. Click the trash icon to delete your script.
For an existing script, click the toggle button of the script you wish to enable. Click the play button of the script you wish to execute. Click the edit pencil icon to update the script, and the trash icon to delete it.
Networks
Wi-Fi
Register Shelly Device to connect to up to 2 different Wi-Fi networks. Either input or select the Wi-Fi network. Can select an open network, and also set a static IP address. Enable Wi-Fi 1, or Wi-Fi 2, or both at the same time. If both Wi-Fi 1 and Wi-Fi 2 are enabled, and Shelly Device disconnects from one of the networks, it will connect to the other. Click the Save
button to save any changes made.
Access Point
Click the checkbox to enable this function. Enable to configure Shelly Device to create a Wi-Fi Access Point (AP), to which you can connect. Observe the SSID. Set a password to protect your device’s access point to secure your network from unauthorized access. Click the checkbox to set the AP it to be an open network. Click the Save
button to save any changes made.
Range extender
Click the toggle button to enable range extender.
Outbound websocket
Click the checkbox to enable SSL connectivity. See outbound websocket status as Connected or Disconnected. Select the type of SSL connectivity from the dropdown menu, and input the server address. Please note changing these settings requires a device reboot. Click the Save
button to save any changes made.
RPC over UDP
Input the destination address and port. Afterwards, input the listening port. Click the Save
button to save any changes made.
Cloud
Enable to connect Shelly Device to its cloud. This allows you to control it remotely, and receive notifications and updates about your devices. Click the toggle button to enable this function.
To disable the cloud connection, click the toggle button again. A confirmation prompt will appear. Click the Confirm
button if you're certain you want to disable the cloud connection for this device.
Bluetooth
Click the checkbox to enable Bluetooth. Click the toggle button to enable RPC and/or Bluetooth gateway.
MQTT
Click the checkbox to enable MQTT. Configure the Shelly Device to execute actions via MQTT. Please note changing the MQTT settings requires a device reboot.
Choose the connection type, choose from the following options:
RPC status notifications over MQTT
Generic status update over MQTT
SSL connectivity
Input the MQTT prefix, the desired server, and client ID.
Input the username and password.
Click the
Save
button to save any changes made.
Safety
With power metering capabilities, the Shelly Device precisely monitors your appliances power consumption.
Max Power Protection
Configure Shelly Device to turn off when power consumption reaches a set value in watts (W). Please note the power range you can set is 0 W - 2300 W.
Max Voltage Protection
Configure Shelly Device to turn off when voltage reaches a set value in volts (V). Please note the max voltage you can set is 280 V.
Max Current Protection
Configure Shelly Device to turn off when the current reaches a set value in amperes (A). Please note the max current you can set is 10 A.
Overvoltage Auto Recovery
Click the toggle button to enable the auto recovery state before the overvoltage happens.
Application Settings
Appliance Type
Select the appliance type to which the Shelly Device is connected to. Choose one of the following from the dropdown menu: Lighting / Entertainment / Heating/cooling / Refrigeration / Laundry & cleaning / Cooking / Pool and Garden / Electric vehicle / Ventilation / Grid source / Solar source / Water heater / Roller / Other. Click the Save
button to save any changes made.
Consumption Calculation
Enable/disable exclusion of device from total room/account consumption. Click the APPLY
button to save any changes made.
Pin lock
Enable/disable PIN lock for this Shelly Device.
Sync Name
Keep the device name in sync with the name given in the app.
Exclude From Activity Log
Click the checkbox to disable event log reports for this device.
Share
Input an email and share control of the Device with another Shelly Smart Control user. The other user will only have access to the Main Controls, Notifications, Charts, and Application Settings tabs, and the Device Information on the Settings tab. The other user cannot see the other device tabs. View which email accounts this Shelly Device has been shared with, and click the delete button to the right of the email account you would like to delete. If a device has been shared with your account, view which account shared the device with you, and click the Remove from my account
button if you wish to delete it from your account.
Settings
Eco Mode
Click the checkbox to enable/disable Eco mode. Device will consume less energy and run at a lower temperature. Device will reboot if you disable/enable this function.
Input/Output Settings
Set relay power on default:
On: Configure Shelly device to Turn ON, when it has power.
Off: Configure Shelly device to Turn OFF, when it has power.
Restore last: Configure Shelly device to Restore the last mode it was in, when it has power.
Match input: Operates the Shelly device according to the state of the switch or button connected to the device
Device Name
Input a name to change the current device name. This will reflect on the device name in the application if the “Sync name” application setting is enabled. Click the SAVE
button to save any changes made.
Firmware Version
Shows your current firmware version. If a newer version is available, you can update your Shelly device by clicking the Update
button.
Geo Location And Time Zone
Set your time zone and geo-location in one of three ways:
Select it manually by choosing your Time zone from the dropdown menu.
Select your location from the map by clicking
Select from map
button.Enable automatic detection by clicking the
Auto detect location
button.
Device Reboot
Reboot your Shelly Device.
Factory Reset
Reset your Shelly Device to its factory settings by clicking the Factory reset
button. This will disconnect the Shelly Device from your Wi-Fi network, and all associated users, including you, will be removed from this Device. All previously set data will be deleted.
Device Information
Here you can view the ID, IP and other settings of your device. Copy Device ID, Decimal ID, Device IP, and Device Type by clicking the copy icon to the right of each.