Shelly Plus H&T Device Smart Control
Main Controls
Below the Main Controls heading, observe the current room humidity and Shelly Device battery as a percentage.
View the temperature chart at the bottom of this tab, which displays the temperatures measured in the last 24 hours. Below the temperature chart is the current measured temperature.
Notifications
If you have Shelly Device notifications, they will appear on this tab. View the number of notifications for this Shelly Device. Tap the X
button in the top right corner of the notification box if you wish to delete the notification.
Charts
Temperature
Observe a chart of the room temperature, with the maximum and minimum temperatures. The blue line chart displays the minimum temperature. The red line chart displays the maximum temperature. Above the temperature chart, you can select the time interval and the date from which you want data to be shown. Drag your finger/mouse across the chart to view time specific temperature measurement. Tap the blue icon to the right of the date interval, above the chart, and change the displayed chart style.
Tap on the expand icon in the top right corner of the Temperature rectangular box if you wish to view the chart in full screen. Below the temperature chart, observe the average, maximum, and minimum temperature values in the specified time range. Below these values, you can tap Export .csv
to download the temperature data as a CSV file.
Humidity
Observe a chart of the room humidity. Above the humidity chart, you can select the time interval and the date from which you want data to be shown. Drag your finger/mouse across the chart to view time-specific humidity measurements. Tap the blue icon to the right of the date interval, above the chart, and change the displayed chart style.
Tap the expand icon in the top right corner of the Humidity rectangular box if you wish to view the chart in full screen. Below the humidity chart, observe the average, maximum, and minimum humidity values in the specified time range. Below these values, you can tap Export .csv
to download the humidity data as a CSV file.
Activity log
Observe the recorded history of the Shelly Device events. See the date and time, and tap the dropdown button to observe the room temperature, the Shelly Device battery as a percentage, and room humidity as a percentage.
Sensor settings
Temperature units
Select ºC/ºF to be the units shown for the temperature on the display and on the app.
Temperature offset
Set the humidity offset by inputting a value between -50°C and 50°C, or between -90°F and 90°F (depending on the chosen units for temperature). Tap Save
to save any changes made.
Humidity offset
Set the humidity offset by inputting a value between -50°C and 50°C, or between -90°F and 90°F (depending on the chosen units for temperature). Tap Save
to save any changes made.
Temperature Threshold
Enter a value for the threshold temperature change, which will cause the Device to wake up and trigger a sensor data report. Enter a value between 0.5°C and 5°C, or between 2°F and 9°F (depending on the chosen units for temperature). Tap Save
to save any changes made.
Humidity Threshold
Enter a value for the threshold relative humidity change which will cause the Device to wake up and trigger a sensor data report. Enter a value between 1 and 20. Tap Save
to save any changes made.
Actions
Use events to trigger http endpoints. You can add up to 20 web hooks. Set up the following settings, and navigate between pages by tapping the Next
or Back
buttons. Tap Add action
to create an action:
Set Action Name: Enter the action name.
Active Time: Mark the checkbox to set an active time. You may leave as the 24-hour default option or choose an active start and end time. Tap the up/down buttons, or type in a number, to set a time in hours and minutes.
When: Select from two conditions.
Temperature change: The event is executed based on the configured threshold. Select the Condition from the dropdown menu: Any / less than / greater than. If less than / greater than is chosen as a condition, enter the temperature threshold value.
Humidity change: The event is executed based on the configured threshold. Select the Condition from the dropdown menu: Any / less than / greater than. If less than / greater than is chosen as a condition, enter the humidity threshold value.
Repeat When: Enter the minimum interval, in seconds, between two consecutive invocations of the webhook. Any events that trigger the webhook within the specified time interval will be automatically suppressed.
Actions: Enter a URL to send the Shelly Device a command. You may add up to 5 URLs per action, which will be executed one after the other. Tap
+ Add URL
to add another URL to execute, or tap+ Add action from another device
to add an action from another device. If you choose to add an action from another device, set it as a Control Output / Toggle Output local action, and set the action as On/Off.Tap
Save
to save the action or to save any changes made.
This function requires a working connection to the Internet. Once the action has been created, it will appear as a rectangular box on the main Actions page for the Shelly Device. You can enable/disable an action by tapping the toggle button to the left of the action box. You can edit the action by tapping on the edit pencil icon on the right, and delete the action by tapping the trash icon on the right.
Please note that actions, in general, reduce battery life. In particular, actions such as HTTPS actions can shorten battery life by half.
Networks
Wi-Fi
Register Shelly Device to connect to up to 2 different Wi-Fi networks. Either input or select the Wi-Fi network. Can select an open network, and also set a static IP address. Enable Wi-Fi 1, or Wi-Fi 2, or both at the same time. If both Wi-Fi 1 and Wi-Fi 2 are enabled, and Shelly Device disconnects from one of the networks, it will connect to the other. Tap Save
to save any changes made.
Access Point
Mark the checkbox to enable this function. Enable to configure Shelly Device to create a Wi-Fi Access Point (AP), to which you can connect. Observe the SSID. Set a password to protect your device’s access point to secure your network from unauthorized access. Mark the checkbox to set the AP it to be an open network. Tap Save
to save any changes made.
Outbound Websocket
View outbound websocket status as Connected or Disconnected. Mark the checkbox to enable SSL connectivity. Please note changing these settings requires a device reboot. Tap Save
to save any changes made.
RPC over UDP
Enter the destination address and port. Afterwards, enter the listening port. Tap Save
to save any changes made.
Cloud
Enable to connect Shelly Device to its cloud. This allows you to control it remotely, and receive notifications and updates about your devices. Tap the toggle to enable this function.
To disable the cloud connection, tap the toggle again. A confirmation prompt will appear. Tap Confirm
if you're certain you want to disable the cloud connection for this device.
Bluetooth
Mark the checkbox to allow Bluetooth communication. Tap the toggle to enable Bluetooth RPC.
MQTT
Mark the checkbox to enable MQTT. Configure the Shelly Device to execute actions via MQTT. Please note changing the MQTT settings requires a device reboot.
Choose the connection type, choose from the following options:
RPC status notifications over MQTT
Generic status update over MQTT
SSL connectivity
Enter the MQTT prefix, the desired server, and client ID.
Enter the username and password.
Tap
Save
to save any changes made.
Application Settings
Offline Notifications
Tap the toggle next to each of the following notification types to enable them:
Enable offline email notifications.
Enable offline push notifications.
Device Card Customization
You can customize both big and small parameter slots on your device’s card. After customization, changes apply everywhere that you see the device in the app. Tap Customize device card
to customize device card.
Choose to customize the Big Parameter Slot or Small Parameter Slot.
Big Parameter Slot:
Choose the slot as one of the following: None / Parameter.
If you choose the slot content as Parameter, select the parameter type from the dropdown menu.
View the preview below.
Small Parameter Slot:
View the list of Selected Parameters and Additional Parameters.
Tap the add
+
button to add the Available Parameters. If you wish to remove a parameter, tap the subtract-
button.Tap the move button, and drag and drop the parameter to the desired position under Selected Parameters.
View the preview below.
Tap
Save
to save any changes made.
Exclude From Activity Log
Tap the toggle to exclude this Shelly Device from the global activity log.
Share
Input an email and share control of the Device with another Shelly Smart Control user. The other user will only have access to the Main Controls, Notifications, Charts, and Application Settings tabs, and the Device Information on the Settings tab. The other user cannot see the other device tabs. View which email accounts this Shelly Device has been shared with, and click the delete button to the right of the email account you would like to delete. If a device has been shared with your account, view which account shared the device with you, and tap Remove from my account
if you wish to delete it from your account.
Settings
Device Name
Change the current device name. Tap the toggle to sync the device name. Keep the device name in sync with the name given in the application if “Sync name” is enabled. The sync is only from the application to the device and not vice-versa. Tap Save
to save any changes made.
Firmware Version
Shows your current firmware version. Tap Check for update
to check if a firmware update is available. If a newer firmware version is available, you can update your Shelly device by tapping Update
.
Geo Location And Time Zone
Set your time zone and geo-location in one of three ways:
Select it manually by choosing your Time zone from the dropdown menu.
Set the Daylight saving time as on / off / auto.
Enter your location Latitude and Longitude.
Select your location from the map by tapping
Select from map
.Enable automatic detection by tapping
Auto detect location
.
Tap Save
to save any changes made.
Device Reboot
Tap Reboot
to reboot your Shelly Device.
Factory Reset
Reset your Shelly Device to its factory settings by tapping Factory reset
. This will disconnect the Shelly Device from your Wi-Fi network, and all associated users, including you, will be removed from this Device. All previously set data will be deleted.
Device Information
Here, you can view the ID, IP, and other settings of your device. Copy Device ID, Decimal ID, Device IP, and Device Type by tapping the copy icon to the right of each. Tap Delete
if you wish to remove the Shelly Device from your account.