Shelly 2.5 Device Smart Control - Relay Mode
Main Controls
Below the Main Controls heading, observe the current Shelly Device power in Watts (W), and voltage in Volts (V).
Above the power button is the Shelly Device’s consumption chart showing power consumption in Watts (W) of the last 24 hours, and the power consumption value in Watts (W).
The power button ⏻
is at the bottom of this tab. Click the power button ⏻
to turn your device On/Off. Your device is on when there is a blue ring around the power button ⏻
, and is off when the ring is gray.
Notifications
If you have Shelly Device notifications, they will appear on this tab. View the number of notifications for this Shelly Device. Tap the X
button in the top right corner of the notification box if you wish to delete the notification.
Charts
Consumption
Observe a chart with the Shelly Device consumption displayed in Watt-hours (Wh). Above the consumption chart, you can select the time interval and the date from which you want data to be shown. Click on the expand icon in the top right corner of the Consumption rectangular box if you wish to view the chart in full screen. Click the Export CSV
button to download this data as a CSV file.
Voltage
Observe a chart with the Shelly Device maximum and minimum voltage displayed in Volts (V). Above the voltage chart, you can select the time interval and the date from which you want data to be shown. Drag your finger/mouse across the chart to view time specific voltage measurements. Tap the blue icon to the right of the date interval, above the chart, and change the displayed chart style.
Below the voltage chart are a variety of Shelly Device measurements. Observe the average, maximum, and minimum Shelly Device voltage in Volts (V).
Tap on the expand icon in the top right corner of the Voltage rectangular box if you wish to view the chart in full screen. Tap Export .csv
to download this data as a CSV file.
Activity log
Observe the recorded history of the Shelly Device events. See the date, time and type of action executed such as the Device being switched On/Off.
Timer
In this tab, you can set a timer to manage the device on/off state.
Choose from the following options:
Auto on: Enter the number of seconds that should pass for the device to be switched on after it has been turned off. Mark the empty checkbox to enable the timer.
Auto off: Enter the number of seconds that should pass for the device to be switched off after it has been turned on. Mark the empty checkbox to enable the timer.
Tap Save to confirm the setting.
Schedule
Click the Add schedule
button to create a schedule. Create a weekly schedule for the day(s) and time(s) you want the corresponding device to turn On/Off automatically. You may add up to 20 weekly schedules. This function requires a working connection to the Internet.
Select the day(s) of the week. Click the
NEXT
button.Choose time interval: Time, or Sunrise / Sunset, and set the time for the previously selected day(s):
Time: Click up/down button, or type in a number, to set a time in hours and minutes. Set the time as AM/PM.
Sunset / Sunrise: The Shelly device may turn on/off automatically at sunrise/sunset, or at a specified time Before/After Sunrise/Sunset. Select the time in hours and minutes from the dropdown menus.
Select action: Select the action as On / Off.
Click the
Save
button to save the schedule or any changes made.
Once the schedule has been created, it will appear as a rectangular box on the main Schedule page for the Shelly Device. On this box, you can see the schedule details such as the days of the week, action and time. You can enable/disable a schedule by clicking the toggle button on the left of the schedule box. You can edit the schedule by clicking on the edit pencil icon on the right, and delete the schedule by clicking the trash icon on the right.
Actions
For each possible condition, click the toggle button to enable the condition. Click the edit icon to add URLs to trigger http endpoints. Click the + Add URL
button to input up to 5 URLs. Click the trash icon to the right of a URL to delete it. Click the Save
button to save any changes made. Possible conditions are:
Button on
Button off
Long push
Short push
Output on
Output off
This function requires a working connection to the Internet. Once you have added URLs to the conditions, you can enable/disable an action by clicking the toggle button to the left of the action box. You can edit the action by clicking on the edit pencil icon on the right. Please note that more than 2 actions can affect the normal operation of the device depending on the network infrastructure and the controlled devices.
Networks
Wi-Fi
Register the Shelly device to connect to up to 2 different Wi-Fi networks. Either input or select the Wi-Fi network. Can select an open network, and also set a static IP address. Enable Wi-Fi 1, or Wi-Fi 2, or both at the same time. If both Wi-Fi 1 and Wi-Fi 2 are enabled, and the Shelly device disconnects from one of the networks, it will connect to the other.
Access Point
Click the checkbox to enable this function. Enable to configure Shelly Device to create a Wi-Fi Access Point (AP), to which you can connect. Observe the SSID. Set a password to protect your device’s access point to secure your network from unauthorized access. Click the Save
button to save any changes made.
Wi-Fi AP Roaming
Click the checkbox to enable Wi-FI AP roaming. Select an a RSSI signal strength value from the dropdown menu, below which the device will periodically scan for a better access point. Click the Save
button to save any changes made.
Restrict Login
Restrict the web interface of the Shelly Device with a username and password. Click the checkbox to enable this function. Click the Save
button to save any changes made.
Cloud
Enable to connect Shelly Device to its cloud. This allows you to control it remotely, and receive notifications and updates about your devices. Click the toggle button to enable this function.
To disable the cloud connection, click the toggle button again. A confirmation prompt will appear. Click the Confirm
button if you're certain you want to disable the cloud connection for this device.
Safety
With power metering capabilities, the Shelly Device precisely monitors your appliances power consumption.
Max Power Protection
Click the checkbox to enable custom Max power protection. Configure Shelly Device to turn off when power consumption reaches a set value in watts (W). Please note the power range you can set is 0 W - 2300 W. Click the Save
button to save any changes made.
Application Settings
Appliance Type
Select the appliance type the Shelly Device is connected to and operating. Choose the following from the dropdown menu:
Lighting
Entertainment
Heating/cooling
Refrigeration
Laundry and cleaning
Cooking
Pool and garden
Electric vehicle
Ventilation
Grid source
Solar source
Water heater
Roller
Other
Source
Select the generated energy type. Choose from the following options:
Grid source
Generated energy
Click the Save
button to save any changes made.
Consumption Calculation
Click the toggle button to enable/disable exclusion of device from total room/account consumption. Click the toggle button to use the device to record peak consumption. Click the APPLY
button to save any changes made.
Input State Display
Turn on indicator for the current status of the physical switch connected to Shelly Device. When enabled, a small line appears on the power button, below the power symbol ⏻
. A red line indicates the physical switch is off, while a blue line indicates the physical switch is on.
Pin Lock
Click the toggle button to enable/disable and set Shelly Device pin lock.
Exclude From Activity Log
Click the toggle button to exclude this Shelly Device from the global activity log.
Forgotten Lights Reminder
You can enable the device “Forgotten Lights Reminder” if your device is designated as a “light” in the “Appliance type” setting. Click the first toggle button to enable forgotten lights tracking. Click the next toggle buttons to enable forgotten lights email and push notifications.
Device Notifications
Click the toggle button next to each of the following notification types to enable them:
Enable device problem email notifications
Enable device problem push notifications.
Enable offline email notifications.
Enable offline push notifications.
Enable over power email notifications.
Enable over power push notifications.
Enable overtemperature email notifications.
Enable overtemperature push notifications.
Share
Input an email and share control of the Device with another Shelly Smart Control user. The other user will only have access to the Main Controls, Notifications, Charts, and Application Settings tabs, and the Device Information on the Settings tab. The other user cannot see the other device tabs. View which email accounts this Shelly Device has been shared with, and click the delete button to the right of the email account you would like to delete. If a device has been shared with your account, view which account shared the device with you, and tap Remove from my account
if you wish to delete it from your account.
Settings
Eco Mode
Click the toggle button to enable/disable Eco mode. Device will consume less energy and run at a lower temperature. Device will reboot if you disable/enable this function.
Operation mode
Set the operation mode of this Shelly Device.
Relay - this mode has ON and OFF states. It is applicable for various appliances such as Lights, Sockets, etc.
Roller Shutter - this is mode is usable for different variants of Door and Window Rollers. It supports UP, DOWN and STOP commands, and provides different settings.
Power on Default
On: Configure Shelly device to Turn ON, when it has power.
Off: Configure Shelly device to Turn OFF, when it has power.
Restore last mode: Configure Shelly device to Restore the last mode it was in, when it has power.
SWITCH: Operates the Shelly device according to the state of the switch or button connected to the device.
Long Push
Set a time to register as a long push in milliseconds (ms).
Button Type
Momentary: Set Shelly device to be "Momentary" switch. Push for "ON" or Push for "OFF".
Toggle Switch: Set Shelly device to be "Toggle" switch. Act as a flip switch with one state for "ON" and one state for "OFF".
Edge Switch: Set Shelly device to be "Edge" switch. Changes state on every hit.
Detached Switch: Set Shelly Device to be in "Detached" switch mode - switch is separated from the relays.
Activation Switch: Use it for motion sensor. Any input turns “ON” and resets Auto OFF timer.
Cycle Switch: At the push of a button, the sequence is Ch1-On Ch2-Off, Ch1-Off Ch2-On, Ch1 & Ch2 On, Ch1 & Ch2 Off.
Reverse inputs: If you enable this option, the buttons On/Off position will be inverted.
LED status disable
Click the toggle button to disable Wi-Fi status LED.
Device Card Customization
You can customize both big and small parameter slots on your device’s card. After customization, changes apply everywhere that you see the device in the app. Click the Customize device card
button to customize device card.
Choose to customize the Big Parameter Slot or Small Parameter Slot.
Big Parameter Slot:
Choose the slot as one of the following: None / Action / Parameter.
If you choose the slot content as Parameter, select the parameter type from the dropdown menu.
View the preview below.
Small Parameter Slot:
View the list of Selected Parameters and Additonal Parameters.
Click the add
+
button to add the Available Parameters. If you wish to remove a parameter, click the subtract-
button.Click the move button, and drag and drop the parameter to the desired position under Selected Parameters.
View the preview below.
Click the
Save
button to save any changes made.
Firmware Version
Shows your current firmware version. If a newer version is available, you can update your Shelly device by clicking the Update
button.
Geo Location And Time Zone
Set your time zone and geo-location in one of three ways:
Select it manually by choosing your Time zone from the dropdown menu.
Set the Daylight saving time as on / off / auto.
Input your location Latitude and Longitude.
Select your location from the map by clicking
Select from map
button.Enable automatic detection by clicking the
Auto detect location
button.
Click the Save
button to save any changes made.
Device Name
Change the current device name. This will reflect on the device name in the settings. Click the Save
button to save any changes made.
Channel Name
Change the current channel name. Click the toggle button to sync channel name. This will reflect on the Shelly Device name in the application if the “Sync name” application setting is enabled. The sync is only from the application to the device and not vice-versa. Click the Save
button to save any changes made.
Factory Reset
Click the toggle button to enable factory reset from input. By enabling this setting, you can reset the Shelly Device from the device input.
Click the toggle button to enable factory reset by power cycle. By enabling this setting, you can reset the Shelly Device by 5 quick successive power cycles.
Click the toggle button to enable factory reset of the Shelly Device from the device input. Reset your Shelly Device to its factory settings by clicking the Factory reset
button. This will disconnect the Shelly Device from your Wi-Fi network, and all associated users, including you, will be removed from this Device. All previously set data will be deleted.
Device Reboot
Click the Reboot
button to reboot your Shelly Device.
Device Information
Here you can view the Shelly Device ID, Device IP, and Device Type, and other device information. Click the clipboard icon to copy the desired information. Click the Delete
button to delete this Shelly Device from your account.