Shelly Wall Display Device Smart Control
Main Controls
Below the Main Controls heading, observe the current room temperature, humidity as a percentage, and whether the room light status is bright or dark.
Above the power button is the room temperature chart of the last 24 hours. The red dot indicates the highest temperature at the specific time, while the blue dot indicates the lowest temperature.
The power button ⏻
is at the bottom of this tab. Click the power button ⏻
to turn your device On/Off. Your device is on when there is a blue ring around the power button ⏻
, and is off when the ring is gray.
Charts
Temperature
Observe a chart with the room temperature. Above the temperature chart, you can select the time interval and the date from which you want data to be shown. Click on the expand icon in the top right corner of the Temperature rectangular box if you wish to view the chart in full screen.
Below the chart, observe the average, max, and min temperature values in specified time range. Below these values, you can click the Export CSV
button to download the temperature data as a CSV file.
Observe a chart with the room humidity. Above the humidity chart, you can select the time interval and the date from which you want data to be shown. Click on the expand icon in the top right corner of the Humidity rectangular box if you wish to view the chart in full screen.
Below the chart, observe the average, max, and min humidity values as a percentage. Click the Export CSV
button to download the humidity data as a CSV file.
Activity log
Observe the recorded history of the Shelly Device events. See the date, time and type of action executed such as the Device being switched On/Off.
Timer
Allows you to manage the power supply automatically. You may use:
Auto on: After turning off, the relay output will be automatically turned on after a predefined time (in seconds).
Auto off: After turning on, the relay output will be automatically turned off after a predefined time (in seconds).
Schedule
Click the Add schedule
button to create a schedule. Create a weekly schedule for the day(s) and time(s) you want the corresponding device to turn On/Off automatically. You may add up to 20 weekly schedules. This function requires a working connection to the Internet.
Select the day(s) of the week.
Advanced Options: Click the downward arrow of Advanced Options to reveal more options.
Active dates: Set the active dates by clicking on the desired date(s). Click on More Options and select from a variety of options:
Select even
/Select odd
/Select all
/Clear
. In addition, you can input the dates From and To you want to set as active dates, and click theSelect
button to choose these dates.Active months: Set the active months by clicking on the desired month(s). Click on More Options and select form a variety of options:
Select even
/Select odd
/Select all
/Clear
. In addition, you can input the months From and To you want to set as active months, and click theSelect
button to choose these months.
Click the
NEXT
button.
Choose time interval: Time, Sunrise / Sunset, Advanced Options, or Random, and set the time for the previously selected day(s):
Time: Click up/down button, or type in a number, to set a time in hours and minutes.
Sunset / Sunrise: The Shelly device may turn on/off automatically at sunrise/sunset, or at a specified time Before/After Sunrise/Sunset. Select the time in hours and minutes from the dropdown menus.
Advanced Options:
Active minutes: Set the active minutes by clicking on the desired minute(s). Click on More Options and select form a variety of options:
Select even
/Select odd
/Select all
/Clear
. In addition, you can input the minutes From and To you want to set as active minutes, and click theSelect
button to choose these minutes.Active hours: Set the active hours by clicking on the desired hour(s). Click on More Options and select form a variety of options:
Select even
/Select odd
/Select all
/Clear
. In addition, you can input the hours From and To you want to set as active hours, and click theSelect
button to choose these hours.Active seconds: Set the active seconds by clicking on the desired second(s). Click on More Options and select form a variety of options:
Select even
/Select odd
/Select all
/Clear
. In addition, you can input the seconds From and To you want to set as active seconds, and click theSelect
button to choose these seconds.
Random: Once you have selected this option, input the number of times that the job will run. Click the up/down button, or type in a number, to set a time in hours and minutes for the start and end time.
Select action: Select Control Output / Toggle Output from the dropdown menu to set the type of local action. If Control Output is selected, set the action as On / Off. Select the target component from the dropdown menu. Click the checkbox to flip value after the set number of seconds, and input the number of seconds.
Once the schedule has been created, it will appear as a rectangular box on the main Schedule page for the Shelly Device. On this box, you can see the schedule details such as the days of the week, action and time. You can enable/disable a schedule by clicking the toggle button on the left of the schedule box. You can edit the schedule by clicking on the edit pencil icon on the right, and delete the schedule by clicking the trash icon on the right.
Sensor Settings
Temperature offset
Set the humidity offset by inputting a value between -50 and 50. Click the Save
button to save any changes made.
Temperature Threshold
Input a value in Celsius (ºC) for the threshold temperature change which will cause the Device to wake up and trigger a sensor data report. (Min: 0.5 ºC - Max: 5 ºC) Click the Save
button to save any changes made.
Humidity offset
Set the humidity offset by inputting a value between -50 and 50. Click the Save
button to save any changes made.
Humidity Threshold
Input a value for the threshold relative humidity change which will cause the Device to wake up and trigger a sensor data report. (Min: 1 % - Max: 20 %) Click the Save
button to save any changes made.
Dark Threshold
Input an illuminance threshold value below which the room illuminance is considered “dark”. Click the Save
button to save any changes made.
Bright Threshold
Input an illuminance threshold value below which the room illuminance is considered “bright”. Click the Save
button to save any changes made.
Actions
Use events to trigger http endpoints. You can add up to 20 web hooks. Set up the following settings, and navigate between pages by clicking the NEXT
or BACK
buttons. Create a web hook:
Set Action Name: Type in action name.
Active Time: May leave as the 24-hour default option or choose an active start and end time. Click the up/down buttons, or type in a number, to set a time in hours and minutes.
When: Select from a variety of conditions for the button/switch. Some conditions may have additional settings to set up. Choose from the following conditions:
Switch on
Switch off
Input on
Input off
Input touch multi touch
Input touch swipe down
Input touch swipe up
Temperature change: This event is executed based on the configured threshold. Select the condition from the dropdown menu as Any / less than / greater than. If you select less than / greater than, then input the temperature below to set the condition.
Temperature measurement: This event is measurement based. The event is executed every 60 seconds, ignoring any threshold configuration. Select the condition from the dropdown menu as Any / less than / greater than. If you select less than / greater than, then input the temperature below to set the condition.
Humidity measurement: This event is executed based on the configured threshold. Select the condition from the dropdown menu as Any / less than / greater than. If you select less than / greater than, then input the humidity as a percentage below to set the condition.
Humidity measurement: This event is measurement based. The event is executed every 60 seconds, ignoring any threshold configuration. Select the condition from the dropdown menu as Any / less than / greater than. If you select less than / greater than, then input the humidity as a percentage below to set the condition.
Illuminance change: This event is executed based on the configured threshold. Select the condition from the dropdown menu as Any / less than / greater than. If you select less than / greater than, then input the value by which the illumination has changed beyond the configured dark/twilight/bright threshold.
Illuminance measurement: This event is measurement based. The event is executed every 60 seconds, ignoring any threshold configuration. Select the condition from the dropdown menu as Any / less than / greater than. If you select less than / greater than, then input the illuminance value measured, regardless of the configured threshold.
Actions: Input URL to send the Shelly Device a command. You may add up to 5 URLs per action, which will be executed one after the other. Click the
Add Action
button to add another URL to execute, or click theAdd local action
button to configure a local action.Local action: Select Control Output / Toggle Output from the dropdown menu to set the type of local action. If you select Control Output as the local action, set the action as On / Off. Click the checkbox to flip value after the set number of seconds.
Click the
SAVE
button to save the web hook or to save any changes made.
This function requires a working connection to the Internet. Once the web hook has been created, it will appear as a rectangular box on the main I/O actions page for the Shelly Device. You can enable/disable an action by click the toggle button to the left of the action box. You can edit the action by clicking on the edit pencil icon on the right, and delete the action by clicking the trash icon on the right.
UI settings
Screen Saver
Click the checkbox to enable screensaver. Set the screensaver timeout by inputting a value between 10 to 3600 seconds. Below this, click the checkboxes to show the clock, temperature, and/or humidity on the screensaver display. Click the SAVE
button to save any changes made.
Screen Lock
Set the screen lock as None / Home / Full. Click the checkbox to disable gestures on locked display. Click the SAVE
button to save any changes made.
UI Settings
Click the corresponding checkboxes to show the following on the user interface (UI)): Show favorites, and/or Show sensor graph. Click the last checkbox to use Fahrenheit instead of Celsius. Click the SAVE
button to save any changes made.
Networks
Wi-Fi
Register Shelly Device to connect to up to 2 different Wi-Fi networks. Either input or select the Wi-Fi network. Can select an open network, and also set a static IP address. Enable Wi-Fi 1, or Wi-Fi 2, or both at the same time. If both Wi-Fi 1 and Wi-Fi 2 are enabled, and Shelly Device disconnects from one of the networks, it will connect to the other.
Outbound websocket
Click the checkbox to enable SSL connectivity. Select the type and input the server address you wish to connect your Shelly Device to. Click the SAVE
button to save any changes made. Please note that changing this setting requires a device reboot.
RPC over UDP
Input a destination address and port. Input a listening port. Click the SAVE
button to save any changes made.
Cloud
Enable to connect Shelly Device to its cloud. This allows you to control it remotely, and receive notifications and updates about your devices.
Bluetooth
Enable to allow Bluetooth communication.
MQTT
Enable to configure Shelly Device to execute actions via MQTT.
Application settings
Pin Lock
Enable and set a device pin lock.
Sync Name
Keep the device name in sync with the name given in the app.
Input State Display
Click the checkbox to add input state identifier to the power button. Click the APPLY
button to apply changes made.
Exclude From Activity Log
Do not show event log reports for this device in the app.
Share
Input an email and share control of the Device with another Shelly Cloud user. The other user will only have access to the Device's power button (on/off), and be able to see the Device Information. The other user cannot see the other device settings.
Settings
Eco Mode
Click the checkbox to enable/disable Eco mode. Device will consume less energy and run at a lower temperature. Device will reboot if you disable/enable this function.
Device Name
Set a name for your device.
Action on power on
On: Configure Shelly Device to Turn ON, when it has power.
Off: Configure Shelly Device to Turn OFF, when it has power.
Restore last: Configure Shelly Device to Restore the last mode it was in, when it has power.
Firmware version
Shows your current firmware version. If a newer version is available, you can update your Shelly device by clicking the Update
button.
Geo Location And Time Zone
Set your time zone and geo-location in one of three ways:
Select it manually by choosing your Time zone from the dropdown menu.
Select your location from the map by clicking
Select from map
button.Enable automatic detection by clicking the
Auto detect location
button.
Device Reboot
Reboot your Shelly Device.
Factory Reset
Reset your Shelly Device to its factory settings by clicking the Factory reset
button. This will disconnect the Shelly Device from your Wi-Fi network, and all associated users, including you, will be removed from this Device. All previously set data will be deleted.
Device Information
Here you can view the Shelly Device ID, IP and other device settings.