Main Controls

Below the Main Controls heading, observe Shelly Device as a percentage. There is a mute button for the alarm sound, and the status of whether or not gas has been detected.

A chart shows the measured gas concentration in ppm of the last 24 hours. Below the chart is mute button for the alarm sound, and the status of whether or not smoke has been detected.

Notifications

If you have Shelly Device notifications, they will appear on this tab. View the number of notifications for this Shelly Device. Click the X button in the top right corner of the notification box if you wish to delete the notification.

Activity log

Observe the recorded history of the Shelly Device events. See the date, time and type of action executed such as whether or not smoke was sensed, and the Shelly Device battery as a percentage.

Actions

Use events to trigger http endpoints. Add URLs to execute when actions are complete. Click the edit pencil icon of the action you wish to activate in order to add URLs.

Add URLs to the following actions:

  • Alarm off

  • Alarm mild

  • Alarm heavy

Follow these steps to add URLs:

  • Click the edit pencil icon next to the action to which you wish to add URLs.

  • Click the + Add URL button to add up to 5 URLs per action, which will be executed one after the other. Click the trash icon if you wish to delete a URL.

  • Click the Save button once you have added your URLs.

Click the toggle button to enable the action. This function requires a working connection to the Internet. Please note that more than two URLs per action can affect the normal operation of the device depending on the network infrastructure and controlled devices.

Networks

Wi-Fi

Register Shelly Device to connect to up to 2 different Wi-Fi networks. Either input or select the Wi-Fi network. Can select an open network, and also set a static IP address. Enable Wi-Fi 1, or Wi-Fi 2, or both at the same time. If both Wi-Fi 1 and Wi-Fi 2 are enabled, and Shelly Device disconnects from one of the networks, it will connect to the other.

Access Point

Click the checkbox to enable this function. Enable to configure Shelly Device to create a Wi-Fi Access Point (AP), to which you can connect. Observe the SSID. Set a password to protect your device’s access point to secure your network from unauthorized access. Click the checkbox to set the AP it to be an open network. Click the Save button to save any changes made.

Outbound websocket

See outbound websocket status as Connected or Disconnected. Click the checkbox to enable SSL connectivity. Please note changing these settings requires a device reboot. Click the SAVE button to save any changes made.

RPC over UDP

Input the destination address and port. Afterwards, input the listening port. Click the Save button to save any changes made.

Cloud

Enable to connect Shelly Device to its cloud. This allows you to control it remotely, and receive notifications and updates about your devices. Click the toggle button to enable this function.

To disable the cloud connection, click the toggle button again. A confirmation prompt will appear. Click the Confirm button if you're certain you want to disable the cloud connection for this device.

Bluetooth

Click the checkbox to enable Bluetooth. Click the toggle button to enable RPC.

MQTT

  • Click the checkbox to enable MQTT. Configure the Shelly Device to execute actions via MQTT. Please note changing the MQTT settings requires a device reboot.

  • Choose the connection type, choose from the following options:

    • RPC status notifications over MQTT

    • Generic status update over MQTT

    • SSL connectivity

  • Input the MQTT prefix, the desired server, and client ID.

  • Input the username and password.

  • Click the Save button to save any changes made.

Application Settings

Exclude From Activity Log

Click the toggle button to exclude this Shelly Device from the global activity log.

Device Notifications

Click the toggle button next to each of the following notification types to enable them:

  • Enable device problem email notifications

  • Enable device problem push notifications.

  • Enable offline email notifications.

  • Enable offline push notifications.

  • Enable smoke alarm email notifications.

  • Enable smoke alarm push notifications.

  • Enable low battery email notifications.

  • Enable low battery push notifications.

Share

Input an email and share control of the Device with another Shelly Smart Control user. The other user will only have access to the Main Controls, Notifications, Charts, and Application Settings tabs, and the Device Information on the Settings tab. The other user cannot see the other device tabs. View which email accounts this Shelly Device has been shared with, and click the delete button to the right of the email account you would like to delete. If a device has been shared with your account, view which account shared the device with you, and click the Remove from my account button if you wish to delete it from your account.

Settings

Device Name

Change the current device name. Click the toggle button to sync device name. This will reflect on the Shelly Device name in the application if the “Sync name” application setting is enabled. The sync is only from the application to the device and not vice-versa. Click the Save button to save any changes made.

Device Card Customization

You can customize both big and small parameter slots on your device’s card. After customization, changes apply everywhere that you see the device in the app. Click the Customize device card button to customize device card.

  • Choose to customize the Big Parameter Slot or Small Parameter Slot.

    • Big Parameter Slot:

      • Choose the slot as one of the following: None / Parameter.

      • If you choose the slot content as Parameter, select the parameter type from the dropdown menu.

      • View the preview below.

    • Small Parameter Slot:

      • View the list of Selected Parameters and Additonal Parameters.

      • Click the add + button to add the Available Parameters. If you wish to remove a parameter, click the subtract - button.

      • Click the move button, and drag and drop the parameter to the desired position under Selected Parameters.

      • View the preview below.

  • Click the Save button to save any changes made.

Firmware Version

Shows your current firmware version. Click the Check for update button to check if a firmware updated is available. If a newer firmware version is available, you can update your Shelly device by clicking the Update button.

Geo Location And Time Zone

Set your time zone and geo-location in one of three ways:

  • Select it manually by choosing your Time zone from the dropdown menu.

    • Set the daylight saving as on / off / auto.

    • Input your location Latitude and Longitude.

  • Select your location from the map by clicking Select from map button.

  • Enable automatic detection by clicking the Auto detect location button. You may also set automatic detection by clicking the checkbox at the top of this section.

Click the Save button to save any changes made.

Device Reboot

Click the Reboot button to reboot your Shelly Device.

Factory Reset

Reset your Shelly Device to its factory settings by clicking the Factory reset button. This will disconnect the Shelly Device from your Wi-Fi network, and all associated users, including you, will be removed from this Device. All previously set data will be deleted.

Device Information

Here you can view the Shelly Device ID, Device IP, and Device Type, and other device information. Click the clipboard icon to copy the desired information. Click the Delete button to delete this Shelly Device from your account.