Shelly Plus PM Mini Device Smart Control
Main Controls
Below the Main Controls heading, observe the current Shelly Device voltage in Volts (V), and current in Amps (A).
Above the power button is a chart of the Shelly Device consumption in Watt-hours (Wh) of the last 24 hours, and the Shelly Device’s current power consumption in Watts (W).
The power button ⏻
is at the bottom of this tab. Click the power button ⏻
to turn your device On/Off. Your device is on when there is a blue ring around the power button ⏻
, and is off when the ring is gray.
Notifications
If you have Shelly Device notifications, they will appear on this tab.
Charts
Consumption
Observe a chart with the Shelly Device consumption displayed in Watt-hours (Wh). Above the consumption chart, you can select the time interval and the date from which you want data to be shown. Drag your finger/mouse across the chart to view time specific consumption measurements. Click the blue icon to the right of the date interval, above the chart, and change the displayed chart style.
Below the consumption chart are a variety of Shelly Device measurements. Observe the Eco (compared) value that gives a percentage of how much lower the consumption value is. In addition, also observe the total consumption value in kilo-Watt-hours (kWh), the average consumption in Watt-hours (Wh), and the maximum and minimum consumption in Watt-hours (Wh).
Click on the expand icon in the top right corner of the Consumption rectangular box if you wish to view the chart in full screen. Click the Export CSV
button to download this data as a CSV file.
Voltage
Observe a chart with the Shelly Device voltage displayed in Volts (V). Above the voltage chart, you can select the time interval and the date from which you want data to be shown. Drag your finger/mouse across the chart to view time specific voltage measurements. Click the blue icon to the right of the date interval, above the chart, and change the displayed chart style.
Below the voltage chart are a variety of Shelly Device measurements. Observe the average, maximum, and minimum Shelly Device voltage in Volts (V). Click on the expand icon in the top right corner of the Voltage rectangular box if you wish to view the chart in full screen. Click the Export CSV
button to download this data as a CSV file.
Actions
Use events to trigger http endpoints. You can add up to 20 web hooks. Set up the following settings, and navigate between pages by clicking the NEXT
or BACK
buttons. Create an action:
Set Action Name: Type in web hook name.
Active Time: Click the checkbox to set an active time. You may leave it as the 24-hour default option or choose an active start and end time. Click the up/down buttons, or type in a number, to set a time in hours and minutes. Set the time as AM or PM.
When: Select from a variety of conditions for the button/switch.
Switch on
Switch off
Input on
Input off
When: Select from a variety of conditions for the action.
When: Select Voltage change / Current change / Active power change from the dropdown menu. These are all threshold based, which means the event is executed based on the configured threshold.
Condition: Select Any / less than / greater than to from the dropdown menu. Depending on your “When” selection, the third setting will be different. When selected from “When” section:
Voltage change: To set the condition, select Any / less than / greater than from the dropdown menu. If less than / greater than is selected, input a voltage in Volts.
Current change: To set the condition, select Any / less than / greater than from the dropdown menu. If less than / greater than is selected, input a current in Amps.
Active power change: To set the condition, select Any / less than / greater than from the dropdown menu. If less than / greater than is selected, input an active power in Watts.
Actions: Input URL to send the Shelly Device a command. You may add up to 5 URLs per action, which will be executed one after the other. Click the
+ Add Action
button to add another URL to execute. Click the trash icon of a URL if you wish to delete it.Click the
SAVE
button to save the web hook or to save any changes made.
This function requires a working connection to the Internet. Once the action has been created, it will appear as a rectangular box on the main Actions page for the Shelly Device. You can enable/disable an action by click the checkbox to the left of the action box. You can edit the action by clicking on the edit pencil icon on the right, and delete the action by clicking the trash icon on the right.
Scripts
Use the Scripts functionality to create or import scripts.
Library: Click the
Open Library
button to view existing scripts. Click on the desired script and click theInsert code
button to add the script to your Shelly Device.Create new script: Click the
Create new script
button. A new page will appear where you can name, create, edit and save your script. Click the play button to run your script. Click thex
button to exit the script. Click the trash icon to delete your script.
For an existing script, click the toggle button of the script you wish to enable. Click the play button of the script you wish to execute. Click the edit pencil icon to update the script, and the trash icon to delete it.
Networks
Wi-Fi
Register Shelly Device to connect to up to 2 different Wi-Fi networks. Either input or select the Wi-Fi network. Can select an open network, and also set a static IP address. Enable Wi-Fi 1, or Wi-Fi 2, or both at the same time. If both Wi-Fi 1 and Wi-Fi 2 are enabled, and Shelly Device disconnects from one of the networks, it will connect to the other.
Access Point
Click the checkbox to enable this function. Enable to configure Shelly Device to create a Wi-Fi Access Point (AP), to which you can connect. Observe the SSID. Set a password to protect your device’s access point to secure your network from unauthorized access. Click the checkbox to set the AP it to be an open network.
Range extender
Click the toggle button to enable range extender. Click the APPLY
button to save any changes made.
Outbound websocket
Click the checkbox to enable SSL connectivity. See outbound websocket status as Connected or Disconnected. Select the type of SSL connectivity from the dropdown menu, and input the server address. Please note changing these settings requires a device reboot. Click the SAVE
button to save any changes made.
RPC over UDP
Input the destination address and port. Afterwards, input the listening port. Click the Save
button to save any changes made.
Cloud
Enable to connect Shelly Device to its cloud. This allows you to control it remotely, and receive notifications and updates about your Shelly devices.
Bluetooth
Enable to allow Bluetooth communication. Enable RPC and/or Bluetooth gateway.
MQTT
Enable to configure Shelly Device to execute actions via MQTT. Select the connection type by clicking its checkbox. Input the MQTT prefix, server address, client ID, username and password. Click the Save
button to save any changes made.
Application Settings
Appliance Type
Select the appliance type to which the Shelly Device is connected to. Choose one of the following from the dropdown menu: Lighting / Entertainment / Heating/cooling / Refrigeration / Laundry & cleaning / Cooking / Pool and Garden / Electric vehicle / Ventilation / Grid source / Solar source / Water heater / Roller / Other. Click the Save
button to save any changes made.
Consumption Calculation
Enable/disable exclusion of device from total room/account consumption. Click the APPLY
button to save any changes made.
Sync Name
Keep the device name in sync with the name given in the app.
Share
Input an email and share control of the Device with another Shelly Smart Control user. The other user will only have access to the Main Controls, Notifications, Charts, and Application Settings tabs, and the Device Information on the Settings tab. The other user cannot see the other device tabs. View which email accounts this Shelly Device has been shared with, and click the delete button to the right of the email account you would like to delete. If a device has been shared with your account, view which account shared it with you, and click the Remove from my account
button if you wish to delete it from your account.
Settings
Eco Mode
Click the toggle button to enable/disable Eco mode. Device will consume less energy and run at a lower temperature. Device will reboot if you disable/enable this function.
Device Name
Set a name for your device.
Firmware Version
Shows your current firmware version. If a newer version is available, you can update your Shelly device by clicking the Update
button.
Geo Location And Time Zone
Set your time zone and geo-location in one of three ways:
Select it manually by choosing your Time zone from the dropdown menu.
Select your location from the map by clicking
Select from map
button.Enable automatic detection by clicking the
Auto detect location
button.
Device Reboot
Reboot your Shelly Device.
Factory Reset
Reset your Shelly Device to its factory settings by clicking the Factory reset
button. This will disconnect the Shelly Device from your Wi-Fi network, and all associated users, including you, will be removed from this Device. All previously set data will be deleted.
Device Information
Here you can view the Shelly Device ID, IP and other device settings.