Shelly Motion 2 Device Page
Status and control
From left to right across the status and control bar, you see the Device image, name, and motion/no motion. Directly below the status and control bar is the current room temperature, illumination status of the room, and Device battery percentage.
If motion is detected by your Shelly Motion 2, then the walking person icon and “motion” will appear on the right-hand side of the control and status bar. If no motion is detected, the standing up person icon and “no” will appear on the right-hand side of the control and status bar.
The status and control bar remains at the top of the Device page, when you click on either the Status and control or Settings tab.
Temperature
Observe a chart with the Shelly Motion 2 recorded temperature given in ºC/ºF (change this under Temperature Units). Above the temperature chart, you can select the time interval and the date from which you want data to be shown. The temperature chart shows the maximum and minimum temperature of the room throughout the chosen time interval. Below the temperature chart you have the option to download the temperature data by clicking the DOWNLOAD
button. This downloads a table of your Shelly Motion 2 temperature data.
If a firmware update is available, then you will observe a "Firmware Update Available" text below the temperature chart. Click the UPDATE
button to update your Shelly Device firmware.
Settings
Sensor Settings
Illumination Definitions
Set illumination values for dark and dusk. Values must be between 0 and 100000.
Motion Settings
Enable/disable the motion sensor.
Set the blind time of the motion sensor in minutes (from 1 to 1440) after the last detected motion. Press the
SAVE
button.Select the sensor’s operating mode: Any / Dark / Twilight / Bright. Input the number of consecutive movements (from 1 to 4) for the sensor to detect before reporting motion. Press the
SAVE
button.Set the motion detection threshold (from 1 to 256) using the slider. A lower value sets higher sensitivity. See motion detection percentage to the right of the slider.
Tamper Sensitivity
Set the temper alarm threshold (from 0 to 80) using the slider. See tamper alarm threshold percentage to the right of the slider.
Sleep Time
Set the number of seconds for the motion detection to pause. Press the SAVE
button.
Temperature Units
Select ºC/ºF to be the units shown the temperature on the display.
Temperature Offset
Set the temperature offset. If you believe your sensor is showing the wrong temperature by a few degree Celsius/Fahrenheit, input the offset value so it displays the correct temp. The value must be between -10 and 10.
Temperature Threshold
Input a value in Celsius (ºC) for the threshold temperature change which will cause the Device to wake up and trigger a sensor data report. (Min: 0.5 ºC - Max: 5 ºC)
Schedule
Create a weekly schedule for the day(s) and time(s) you want the corresponding device to turn On/Off automatically. You may add up to 20 weekly schedules with 5 URLs each.
Select the day(s) of the week.
Choose time interval: time, sunrise, or sunset.
Set the time for the specified day(s):
Time: Click up/down button, or type in a number, to set a time in hours and minutes.
Sunset/Sunrise: The Shelly device may turn on/off automatically at sunrise/sunset, or at a specified time before or after sunrise/sunset. Click up/down button, or type in a number, to set a time in hours and minutes.
Set the action as on/off.
This function requires a working connection to the Internet.
I/O Actions
When motion is detected in any of the conditions below, the sensor will send a separate command when it disappears. The sensor will transmit a new movement after the blind time has elapsed after the last movement.
For each possible condition, check the checkbox to enable the condition. Input up to 5 URLs in order to trigger http endpoints. Set a start and end time for these actions. Possible conditions are:
Motion detected
Motion detected in dark
Motion detected in twilight
Motion detected in bright
End of motion
Dark condition
Twilight condition
Bright condition
Tamper alarm enabled
Tamper alarm disabled
Temperature over
Temperature under
Sensor reports
Internet
Wi-Fi
Register the Shelly device to connect to up to 2 different Wi-Fi networks. Either input or select the Wi-Fi network. Can select an open network, and also set a static IP address. Enable Wi-Fi 1, or Wi-Fi 2, or both at the same time. If both Wi-Fi 1 and Wi-Fi 2 are enabled, and the Shelly device disconnects from one of the networks, it will connect to the other.
Access Point
Enable to configure the Shelly device to create a Wi-Fi AP and you can connect to its network. Can also set it to be an open network.
Restrict Login
Restrict the web interface of the device with a Username and Password.
Application Settings
Exclude From Event Log
Do not show event log reports for this device in the app.
Sync Name
Keep the device name in sync with the name given in the app.
Share
Input an email and share control of the Device with another Shelly Cloud user. The other user will only have access to the Device's power button (on/off), and be able to see the Device Information. The other user cannot see the other device settings.
Settings
LED Status Display
Enable/disable Wi-Fi status LED.
Firmware Version
Shows your current firmware version. If a newer version is available, you can update your Shelly device by clicking the Update
button.
Geo Location And Time Zone
Set your time zone and geo-location manually, or enable/disable automatic detection.
Device Name
Set a name for your device.
Factory Reset
Remove Shelly Device from your account and return it to its factory settings. This will delete all set data.
Device Reboot
Reboot your Shelly Device.
Device Info
Here you can view the ID, IP and other settings of your device. Upon clicking Edit device
, you can change the room, name or image of the device.