Shelly 1PM Device Page

Status and Control

From left to right across the status and control bar, you see the Device image, name, and a power button . Click the power button to turn your device on/off. Your device is on when there is a blue ring around the power button , and is off when the ring is gray. Directly below the status and control bar is the current Device power in watts.

The status and control bar remains at the top of the Device page when you click on either the Status and control or Settings tab.

External Sensors

Observe the temperature recorded by the external sensor. Change the name of the external sensor in the Sensor Names section.

External Temperature Sensor

Observe a chart with the external sensor recorded temperature given in ºC/ºF (change this under Temperature Units). Above the temperature chart, you can select the time interval and the date from which you want data to be shown. The temperature chart shows the maximum and minimum temperature of the room throughout the chosen time interval. Below the temperature chart you have the option to download the temperature data by clicking the DOWNLOAD button. This downloads a table of your the external sensor temperature data.

Consumption

This tab only appears for Shelly Devices with power metering (PM) capabilities.

Observe a chart with the Shelly Device consumption displayed in watt-hours (Wh). Above the consumption chart, you can select the time interval and the date from which you want data to be shown. Below the consumption chart you have the option to download the consumption data by clicking the DOWNLOAD button. This downloads a table of your Shelly Device consumption data.

If a firmware update is available, then you will observe a "Firmware Update Available" text below the Consumption chart. Click the UPDATE button to update your Shelly Device firmware.

Settings

Timer

Allows you to manage the power supply automatically. You may use:

  • Auto on: After turning off, the relay output will be automatically turned on after a predefined time (in seconds).

  • Auto off: After turning on, the relay output will be automatically turned off after a predefined time (in seconds).

Schedule

Create a weekly schedule for the day(s) and time(s) you want the corresponding device to turn On/Off automatically. You may add up to 20 weekly schedules.

  • Select the day(s) of the week.

  • Choose time interval: time, sunrise, or sunset.

  • Set the time for the specified day(s):

    • Time: Click up/down button, or type in a number, to set a time in hours and minutes.

    • Sunset/Sunrise: The Shelly device may turn on/off automatically at sunrise/sunset, or at a specified time before or after sunrise/sunset. Click up/down button, or type in a number, to set a time in hours and minutes.

  • Set the action as on/off.

This function requires a working connection to the Internet.

I/O Actions

Use events to trigger http endpoints. For each possible condition, click the Enable checkbox to enable the condition. Input up to 5 URLs per condition. The possible conditions are:

  • Button on

  • Button off

  • Button long push

  • Button short push

  • Output on

  • Output off

  • Sensor reports

Sensor Actions

Use events to trigger http endpoints. For each possible condition, click the Enable checkbox to enable the condition. Input the temperature over/under value, and input up to 5 URLs per condition. Set the action to be executed One time or Repeatedly. The possible conditions are:

  • External sensor temperature over

  • External sensor temperature end

External Sensors

Temperature Units

Set the temperature units to ºC/ºF.

Sensor Names

Name the external temperature sensor. Click the SAVE button to save any changes made.

Temperature Offset

Input the temperature offset if the external sensor does not measure the true value. Click the SAVE button to save any changes made.

Temperature Automation

Set temperature thresholds for the external sensor. Input the over/under-temperature threshold. Set the over/under temperature action to Disabled / Relay on / Relay Off.

Internet

Wi-Fi

Register the Shelly device to connect to up to 2 different Wi-Fi networks. Either input or select the Wi-Fi network. Can select an open network, and also set a static IP address. Enable Wi-Fi 1, or Wi-Fi 2, or both at the same time. If both Wi-Fi 1 and Wi-Fi 2 are enabled, and the Shelly device disconnects from one of the networks, it will connect to the other.

Access Point

Enable to configure the Shelly device to create a Wi-Fi AP and you can connect to its network. Can also set it to be an open network.

Wi-Fi AP Roaming

Click the Enable checkbox. Set the RSSI signal strength value below which the device will periodically scan for a better access point. Set a value between -50 to -90. Click the APPLY button to apply any changes made.

Restrict Login

Restrict the web interface of the device with a Username and Password.

Cloud

Enable to connect Shelly Device to its cloud. This allows you to control it remotely, and receive notifications and updates about your devices.

Safety

With power metering capabilities, the Shelly Device precisely monitors your appliances power consumption. Click the checkbox to enabled Max Power Protection. Configure Shelly Device to turn off when power consumption reaches a set value in watts (W). Please note the power range you can set is 0 W - 3500 W.

Application Settings

Pin Lock

Enable and set a channel pin lock.

Sync Name

Keep the device name in sync with the name given in the app.

Input State Display

Turn on indicator for the current status of the physical switch connected to Shelly Device. When enabled, a small line appears on the power button, below the power symbol . A red line indicates the physical switch is off, while a blue line indicates the physical switch is on.

Exclude From Event Log

Do not show event log reports for this device in the app.

Consumption Calculation

If your device has power metering capabilities, this application settings is available. Enable/disable exclusion of device from total room/account consumption.

Share

Input an email and share control of the Device with another Shelly Cloud user. The other user will only have access to the Device's power button (on/off), and be able to see the Device Information. The other user cannot see the other device settings.

Settings

Eco Mode

Device will consume less energy and run at a lower temperature. Device will reboot if you disable/enable this function.

Power On Default

Select from the following:

  • On: Configure Shelly Device to turn on when it has power.

  • Off: Configure Shelly Device to turn off when it has power.

  • Restore last mode: Configure Shelly Device to restore the last mode it was in when it has power.

  • SWITCH: Operates the Shelly Device according to the state of the switch connected to the device.

Button Type

Select from the following to set button type:

  • Momentary - Set Shelly device to be a “Momentary” switch. Push-for “ON” or Push-for “OFF”.

  • Toggle Switch - Set this Inputs reader to be a “Toggle” switch. Switch acts as a flip switch with one state for "ON" and one state for "OFF".

  • Edge Switch - edge on/off mode with single switch. Changes state on every hit.

  • Detached Switch - Set this relay to be in “Detached” switch mode - switch is separated from the relays.

  • Activation Switch - use it for a motion sensor. Any input turns “ON” and resets Auto OFF timer.

  • Reverse inputs - If you enable this option, the buttons On/Off position will be inverted.

Long Push

Set the time to register a long push in milliseconds (ms). Click the SAVE button to save any changes made.

External Switch

Click the check box to Enable the external switch. You have the option to enable “Flipping the switch turns output ON/OFF”, and to “Reverse switch position”. Select one of the following as the external switch add-on interface icon: Basic, Door, or Garage.

LED Status Disable

Enable/disable Wi-Fi status LED.

Supply Voltage

Select the voltage supplied to the Shelly Device. Select from 110 or 230 Volts by ticking the checkbox

Consumption Correction

Set the consumption correction. Input a value between 0.85 to 1.15.

Geo Location And Time Zone

Set your time zone and geo-location manually, or enable/disable automatic detection.

Appliance Type

Select the appliance type from the dropdown menu: general, relay, light, socket, heating, or entertainment. Click the SAVE button to save any changes made.

Device Name

Change the current device name. This will reflect on the device name in the application if the “Sync name” application setting is enabled. Click the SAVE button to save any changes made.

Channel Name

Change the current channel name. This will reflect on the device name in the application if the “Sync name” application setting is enabled. Click the SAVE button to save any changes made.

Firmware Update

Shows your current firmware version. If a newer version is available, you can update your Shelly device by clicking the UPDATE button.

Factory Reset

Remove Shelly Device from your account and return it to its factory settings. This will delete all set data.

Device Reboot

Reboot your Shelly Device.

Device Info

Here you can view the ID, IP and other settings of your device.

Upon clicking Edit device, you can change the room, name or image of the device.